Diving Regulators 1st and 2nd Stage

Automatic Mares ULTRA ADJ 82X DIN

Automatic Mares ULTRA ADJ 82X DIN
Automatic Mares ULTRA ADJ 82X DIN
Automatic Mares ULTRA ADJ 82X DIN
Automatic Mares ULTRA ADJ 82X DIN
Automatic Mares ULTRA ADJ 82X DIN
Automatic Mares ULTRA ADJ 82X DIN
Automatic Mares ULTRA ADJ 82X DIN

Automatic Mares ULTRA ADJ 82X DIN

Brand: Mares|EAN code: 792460375728

Unrivaled automatics of the Mares brand, which are created for the most difficult conditions. It meets all requirements according to the EN250 standard even at a depth of 200 m. DESCRIPTION 1st degree DFC on all medium pressure outputs 5 rotating medium pressure outlets Optimized arrangement…

6-8 days

499 €

Product details Automatic Mares ULTRA ADJ 82X DIN

Unrivaled automatics of the Mares brand, which are created for the most difficult conditions. It meets all requirements according to the EN250 standard even at a depth of 200 m.

DESCRIPTION

1st degree

  • DFC on all medium pressure outputs
  • 5 rotating medium pressure outlets
  • Optimized arrangement of high-pressure outlets
  • AST: first stage with dry system
  • Pearl chrome finish
  • Compact size

2. Degree

  • Twin power system (VAD and VAD )
  • Setting the inspiratory resistance
  • PAD: pneumatic balanced second stage
  • Maximum gas supply
  • Ultralight technopolymer
  • Large air shower flip button
  • Superflex hose

It meets all requirements according to the EN250 standard even at a depth of 200 m with a breathing volume of 62.5 l/min calculated as surface consumption (i.e. 1,312.5 l/min at 200 m). Used a mixture of 6.7% oxygen, 83.3% helium and 10% nitrogen. This gas mixture has the same density at 200 m as air at 50 m.

Material: Techno Polymer
First stage: Balanced Diaphragm
HP outputs: 2 HP 7/16" UNF
LP outputs: 5 LP 3/8" UNF

  • Abrasion resistant, ideal for swimming in warm and medium warm waters.
  • It minimizes the drop in central pressure that occurs during the inhalation phase and maximizes air intake, especially in extreme conditions.
  • Flow control, the so-called Twin Power, regulates the amount of gas supplied to the second stage. In the VAD position, breathing feels like traditional Mares, while in the VAD position, the amount of air delivered is higher.
  • All Mares second stages are equipped with a unique patented VAD system. When air flows through the bypass into the mouthpiece, a vortex is created and a vacuum is created in its center. This causes the movement of the diaphragm during the inhalation phase, which has the effect of improving the automatic response and facilitates breathing at any depth.
  • Extremely low weight and extraordinary flexibility guarantee maximum freedom of movement.